Qanary's Quantum-Kernel Study of 24 November 2026: A 0.17 AUC Lead on Simulated Mammograms Falls to 0.002 Against a Random Forest

Quentir Medicine Monitor

Evidence-based insights for quantum medicine. Published by Quentir Systems LLC · November 25, 2026.

Conceptual breast-imaging tissue phantom: a translucent glass dome with fine rose-colored fibrous strands and one small gold star-shaped mass inside, resting on the polished titanium detector plate of a mammography system under a clear compression paddle, in a bright radiology room.

Three researchers at Qanary Inc., a company that develops mammography screening software, tested whether a quantum kernel classifies breast cancer data better than classical machine learning, and found no demonstrated advantage in these experiments. Their preprint, posted to arXiv on 24 November 2026, shows that an apparent lead of 0.1736 in the area under the curve on simulated mammograms shrinks to 0.0019, a statistically nonsignificant difference, once the quantum classifier faces a random forest trained on exactly the same eight input features. Rana Saad, Achraf Toufah and Moulay Youssef El Hafidi report their own negative results and measure how the choice of comparison method and the selective reporting of runs can turn a null result into an apparent advantage.

No quantum computer took part in the study. Every quantum classifier in the paper is an exact simulation of an 8-qubit circuit on ordinary hardware, and the authors state that no quantum component sits in the inference path. They also note that a circuit of 8 qubits lies roughly two orders of magnitude inside the range that classical computers simulate easily, so the study could not have demonstrated a quantum advantage even if its numbers had favored the quantum arm. Its value for clinicians lies in the measurement of how such claims are built.

What Saad, Toufah and El Hafidi tested on three breast cancer datasets

The paper, Quantum kernels on breast data: concentration, surrogates, and two ways an advantage gets manufactured, runs three benchmarks. The first uses the Wisconsin Diagnostic Breast Cancer dataset, 569 cases with 30 measured features of cell nuclei, at ten training-set sizes from 8 to 300 cases. The second uses 1,200 synthetic mammograms from M-SYNTH, a set the US Food and Drug Administration distributes as a Regulatory Science Tool, half with a simulated spiculated mass of 5-millimeter radius and half without, rendered at four breast densities and two radiation doses. The third uses BreastMNIST, a small public set of breast ultrasound images, to measure what happens when a team runs one model many times and reports its best run.

On the Wisconsin data, with every choice of model settings made on the training data alone, the quantum kernel finished behind the top classical method at all ten sizes and was ahead in only 2 of 200 paired comparisons. Its deficit was largest with eight training cases and narrowed to 0.0143 with 300. That shape runs opposite to the sample-efficiency advantage often attributed to quantum learners, which would require the quantum model to lead when data are scarce. The authors add a candid qualification: classical methods already reach an area under the curve of 0.98 with eight cases, so this dataset leaves too little room to detect any advantage at all.

The authors trace the quantum kernel's weakness to its geometry. At its default scale, the similarity scores it assigns to pairs of patients sit barely above the level expected between two random quantum states, so every training case looks equally distant from every other. This effect, called exponential concentration in work by Supanut Thanasilp and colleagues in Nature Communications in 2024, can worsen as qubits are added, depending on the encoding, the circuit and the way the kernel is measured. The automatic tuning procedure rescued performance by shrinking the encoding scale toward the limit where the quantum circuit behaves like a simple classical kernel. The more classical the encoding became, the better the model scored.

Quantum pillar: computing. Technology readiness: TRL 2 of 9. The quantum classifier exists only as an exact simulation on ordinary computers, tested on public and synthetic breast data; it has run on no quantum hardware, seen no patients and supported no clinical decision.

How the comparison method on simulated mammograms produced a lead of 0.17

The central result comes from the M-SYNTH images. On a fixed test set of 352 cases, the highest-scoring quantum kernel reached an area under the curve of 0.7045. Against a tuned support vector machine with a standard Gaussian kernel, which scored 0.5309, that is a lead of 0.1736 with a p-value of 5.2 in a million, an effect 4.3 times the minimum detectable difference of 0.0406 that the study fixed in advance. A random forest given the same eight features scored 0.7026, which leaves a difference of 0.0019 with a p-value of 0.937. The leading classical model using the full feature set scored 0.7551, higher than the quantum kernel, although that difference was not significant (p = 0.105).

The weak comparator was visible before anyone looked at the test results. On the validation data, the Gaussian support vector machine already ranked fourth of the five classical methods tried, and the ranking was identical on the test data. A further sweep of eleven kernel families found that a classical Laplacian kernel scored higher than the quantum kernel on validation, 0.7350 against 0.6872, and would have been reported as the winner under the study's own selection rule. The authors conclude that a protocol which names its comparator in advance, instead of selecting the top performer from a declared set on validation data, will reproduce this error every time, and that pre-registration alone does not prevent it.

Why thirty random seeds and a patient-number leak matter to radiology buyers

The second mechanism is selection. When the team ran one fixed classical model with 30 different random starting points on BreastMNIST, the average area under the curve was 0.7521 and the highest was 0.7732. Reporting only the top run adds 0.0210, which the authors note equals the entire advantage claimed in one of the published quantum studies they examined while preparing the paper. Comparator choice moved the M-SYNTH result by 0.1717 and seed selection moved BreastMNIST by 0.0210; once the M-SYNTH quantum kernel faced the top same-input classical method on raw and on processed images, its positive gaps were 0.0019 and 0.0211, and neither was significant.

The authors also withdrew a fourth benchmark on CMMD, a public Chinese mammography collection. In the fixed data splits, the patient serial number alone predicted malignancy almost perfectly, so a classifier could reach a high score partly by picking up the order in which patients were filed. A hospital evaluating an AI or quantum-AI mammography tool should recognize this pattern, because a score obtained on such a compromised split cannot establish that the model reliably discriminates tumors.

For radiology departments and procurement teams, the paper converts a single headline figure into four checks, which the authors propose as a reporting standard. The comparison must include the top performer from a declared set of classical methods, among them a tuned tree ensemble and a non-Gaussian kernel, chosen on validation data and reported in full. A classical approximation of the quantum kernel must use the same settings as the winning quantum model. The concentration of the kernel must be reported against its random-state floor. Every headline figure must carry its selection discount, the gain obtained from choosing the top run or the top test result. Quentir's Medicine Monitor reached a similar conclusion in September, when simulated quantum kernels lost all 24 matched tests to a default classical support vector machine on brain MRI and breast ultrasound.

What the Qanary authors disclose about funding, registration and one unexplained result

All three authors are Qanary employees, the study was paid from company funds, and two of them are inventors on a pending US patent application on input-integrity gating filed on 17 November 2026. The paper states that it supersedes the framing of the company's earlier quantum-kernel and quantum neural network manuscripts, none of which, it says, is evidence of quantum benefit. Only the M-SYNTH benchmark was registered in advance, in an internal protocol and not a public registry, and the Laplacian sweep that weighs most against the quantum arm was added afterward. M-SYNTH carries realistic X-ray physics but no real anatomy, and library versions for the original runs were not recorded.

One result does not fit. At the largest bandwidth tested, a matched classical Gaussian approximation of the quantum kernel scored 0.5410 against the kernel's 0.7045. The authors decline to read this as a quantum effect, because the random forest already matches the quantum kernel's accuracy, and they leave a learned-approximation test to future work. They measure their claims against the framework for quantum advantage proposed by Olivia Lanes and colleagues at IBM and Pasqal in 2025, which requires a quantum result to be tested against the strongest known classical methods. Quentir's general blog placed this paper beside three other tests of quantum advantage on 25 November in a reading of how classical baselines decide such claims. A quantum-AI mammography claim that reports one quantum arm, one comparator and one test split has not yet been tested against the methods a hospital already has.

Sources

Primary source: Rana Saad, Achraf Toufah and Moulay Youssef El Hafidi (Qanary Inc.), Quantum kernels on breast data: concentration, surrogates, and two ways an advantage gets manufactured, arXiv:2611.32942, version 1 of 24 November 2026. Also drawn on: Lanes and colleagues on a framework for quantum advantage (arXiv, 2025), Thanasilp and colleagues on exponential concentration in quantum kernel methods (Nature Communications, 2024) and earlier Quentir coverage.

  1. Quantum kernels on breast data: concentration, surrogates, and two ways an advantage gets manufactured
  2. exponential concentration
  3. framework for quantum advantage proposed by Olivia Lanes and colleagues at IBM and Pasqal in 2025
Previous
Previous

UOW's Diamond Voltage Imaging Microscope for Motor Neurone Disease: Dzung Do-Ha Receives QUBIC's First Cathy Foley Fellowship, Reported 26 November 2026

Next
Next

Google DeepMind and Google Quantum AI Cut the Quantum Cost of Cytochrome P450 Energy Estimates 2.5-Fold and Memory From 481 to 333 Logical Qubits With Lean-Verified Circuits