Tohoku University Researchers Use Quantum Annealing to Choose Which MRI Lines a Knee Scan Acquires: What arXiv 2611.25625 Tested on fastMRI Images, 19 November 2026

Quentir Medicine Monitor

Evidence-based insights for quantum medicine. Published by Quentir Systems LLC · November 20, 2026.

Conceptual close-up of a translucent human knee joint, with femur, kneecap, tibia and cartilage visible, resting in a sleek open MRI knee coil of clear blue polymer and brushed silver with thin gold receive loops, in a bright glass atrium.

A preprint that Xiaoxin Huang and Masayuki Ohzeki of Tohoku University posted on 19 November 2026 treats a routine decision in accelerated MRI as an optimization problem for an annealer: which lines of raw scanner data a shorter scan should acquire and which it may skip. The authors scored every candidate line by how much information it carries about image quality, combined those scores into a single binary optimization model, and solved it twice, once with classical simulated annealing and once with D-Wave's quantum-classical hybrid solver. On knee images from the public fastMRI collection, the resulting sampling masks reconstructed images with lower average error than four standard sampling patterns at every scan budget the authors tested.

The clinical motive is scan time. A full MRI acquisition can take long enough to be difficult for people with claustrophobia and for patients who cannot lie still, and the authors open their paper with exactly that burden. Acquiring fewer data lines shortens the scan, but every skipped line removes information the reconstruction software must do without. The choice of lines therefore decides how much image quality a department gives up for each minute it saves. The paper proposes a new way to choose the lines and tests it in simulation; no real examination has yet been shortened with it.

How Huang and Ohzeki turned the choice of MRI k-space lines into a QUBO problem

An MRI scanner acquires its signal in k-space, the frequency representation of the image. Lines near the center of k-space carry overall contrast and shape; lines toward the edge carry edges and fine detail. Many accelerated MRI methods use fixed sampling rules. One widely used example is the pseudorandom variable-density sampling that Michael Lustig, David Donoho and John Pauly proposed in their 2007 compressed sensing paper in Magnetic Resonance in Medicine, which samples the center densely and the periphery sparsely. Such rules are written in advance and do not adapt to images of the anatomy being scanned. Later studies, which the preprint reviews, made the mask itself an optimization target: Gözcü and colleagues searched for masks by their average performance on training images, and the LOUPE method learns a sampling distribution jointly with a reconstruction network.

The Tohoku preprint, arXiv 2611.25625, also derives the mask from training images, by way of statistical feature selection. At each target sampling rate the authors generated 1,000 candidate masks, half drawn uniformly at random and half concentrated around the center of k-space, and measured how well each mask reconstructed a set of training images. They then estimated the mutual information between the inclusion of each line and the reconstruction error, and the conditional mutual information for pairs of lines, which measures how strongly one line's inclusion is associated with reconstruction error once the selection state of another line is known. A penalty term favors selections whose number of lines matches the scan budget. Together these terms form a quadratic unconstrained binary optimization model, or QUBO, in which each line is a yes-or-no variable and the preferred mask is the lowest-energy configuration.

QUBO models are the native input format of quantum annealers, which is where the quantum element enters. The authors solved each model with simulated annealing in the classical dwave-neal package, and with D-Wave's hybrid binary quadratic model solver, reached through the LeapHybridSampler interface with a three-second time limit. D-Wave's documentation describes its hybrid solvers as classical algorithms combined with allocation of the quantum computer to the parts of a problem where it benefits most. The preprint does not report how much of each solution the quantum processor itself contributed.

Quantum pillar: computing. Technology readiness: TRL 3 of 9. The method has run on a commercial quantum-classical hybrid solver with real patient knee images, but the shortened scans were simulated from processed images, and no scanner has acquired data with these masks.

What the fastMRI knee test showed at sampling rates from 15 to 40 percent

The test data came from the single-coil knee portion of fastMRI, the open dataset that NYU Langone Health and Facebook AI Research released for accelerated MRI research and that Knoll and colleagues described in Radiology: Artificial Intelligence in 2020. The authors trained on 200 image slices from 25 patients and tested on 60 slices from five other patients, so that no patient appeared on both sides. They tested six scan budgets, from 15 to 40 percent of the full set of lines, repeated the whole procedure five times with different random seeds, and compared their masks with variable-density, Gaussian, uniform random and roughly equally spaced sampling.

Both QUBO variants gave lower mean reconstruction error and higher peak signal-to-noise ratio than all four conventional patterns at all six budgets. At 30 percent sampling, the mean root mean square error was 0.05256 with simulated annealing and 0.05252 with the hybrid solver, against 0.05879 for variable-density sampling, the strongest conventional method on that measure: a reduction of about 10.6 to 10.7 percent. The advantage narrowed as the budget grew. On structural similarity, a measure closer to how a reader perceives anatomy, equally spaced sampling scored highest at 40 percent. Against a simpler baseline that ranks lines one at a time by mutual information, the QUBO masks won on error at 15, 35 and 40 percent and lost at 20 to 30 percent, while scoring higher on structural similarity at every budget.

The two solvers produced closely matching scores. The improvement therefore comes from the information-theoretic formulation, and classical simulated annealing achieves it about as well as the hybrid solver at this problem size. The authors leave a systematic comparison of solver cost and solution quality to future work.

What a radiology department would need before such masks reach a scanner

The authors set out the limits of their own evaluation. The shortened scans were simulated by applying masks to the Fourier transform of processed magnitude images, without noise. The raw complex-valued data a scanner acquires were not used. Each reference and reconstructed image was normalized separately, so the metrics do not test whether signal intensities are preserved. Most comparisons used zero-filled reconstruction, the simplest method, while clinical systems reconstruct undersampled data with far more capable algorithms. The test set held five patients and one anatomy. The authors propose more patients, other acquisition conditions, raw k-space data and comparison with learning-based mask optimization as the next steps.

One feature of the method matters for hospitals planning equipment. The optimization runs once, offline, before any patient is scanned. Its output is a fixed list of k-space lines, so a department using such a mask would not need access to a quantum computer at the time of the examination. Implementing the mask in a scanner's pulse sequence has not been tested. Earlier Quentir coverage of a Florence and Barcelona diffusion model that ran its noise step on IBM's 133-qubit Torino processor showed the same division of labor in a different form: quantum hardware handles one step of an imaging pipeline, and classical software does the rest.

For MRI vendors and academic imaging groups, the open question is whether masks chosen this way keep their advantage under the reconstruction methods and multi-coil receiver arrays used in routine practice. The question for D-Wave and other annealing providers is whether a quantum processor ever finds better masks than classical annealing once the number of lines and the pairwise terms grow large. The preprint answers neither question yet. Its contribution is a fully specified formulation and a test on public patient data against which later methods can be compared. The work was funded by the Cabinet Office of Japan's Cross-ministerial Strategic Innovation Promotion Program and by JST BOOST.

Sources

Primary source: preprint by Xiaoxin Huang and Masayuki Ohzeki (Tohoku University), arXiv, 19 November 2026. Also drawn on: the fastMRI dataset paper by Florian Knoll and colleagues (2020), the compressed sensing MRI paper by Michael Lustig, David Donoho and John Pauly (2007), D-Wave's documentation of its hybrid solvers and earlier Quentir coverage.

  1. their 2007 compressed sensing paper in Magnetic Resonance in Medicine
  2. Tohoku preprint, arXiv 2611.25625
  3. D-Wave's documentation describes its hybrid solvers
  4. Knoll and colleagues described in Radiology: Artificial Intelligence in 2020
Previous
Previous

Qubit Pharmaceuticals, Sorbonne Université and Q-CTRL Predict Where Water Sits in Drug-Target Protein Pockets on IBM Heron Processors at up to 123 Qubits: What Physical Review Research Published

Next
Next

QuEra's Yuval Boger Expects Materials Before Drug Discovery on Fault-Tolerant Quantum Computers: What the Harvard, Anthropic and QuEra Preprint arXiv 2610.22367 Cut From Chemistry Circuits